Architecture
Economic and administrative sciences
- Economy
- Business Administration
- Statistics and Actuarial Sciences
- International Business
- Project Management Specialization
- Business Management Specialization
- ???jsp.home.menu-lumieres.ehuman???
- Occupational Health and Safety Management Specialization
- International Business and Economic Integration Specialization
- Master MBA Administration
- Master Degree in Human Talent Management
Sciences and Humanities
Engineering
- Industrial engineering
- Mechanical Engineering
- Petroleum engineering
- Chemical engineering
- Environmental engineering
- Energy Engineering
- Mechatronics Engineering
- Quality Management Specialization
- Environmental Management Specialization
- Master in Environmental Management for Competitiveness
- Master Degree in Comprehensive Quality and Productivity Management
- Reservoir Engineering Master
- Master in Advanced Hydrocarbon Recovery
Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.11839/7324
Title: | Diseño de sistema de recuperación de calor de aire caliente de desecho para calentamiento y vaporización de agua en la compañía Vidrio Andino S.A. |
Other Titles: | Design of a heat recovery system from wasted hot air for heating and steaming of water in Vidrio Andino S.A. Company |
Authors: | Moreno Beltrán, Julián David |
License type: | Atribución – No comercial – Sin Derivar |
Keywords: | Sistema recuperación;Aire caliente;Diseño;Recovery system;Hot Air;Design;Tesis y disertaciones académicas |
Issue Date: | 21-Feb-2019 |
Publisher: | Fundación Universidad de América |
Resumen: | Para desarrollar el presente proyecto de grado fue necesario tener conocimiento y realizar un análisis detallado de las necesidades de la compañía Vidrio Andino S.A. enfocado en las oportunidades de mejora para la recuperación de calor. El proyecto inició con la etapa de investigación y análisis de proceso en la que se encontraron pérdidas de calor potencialmente aprovechables en la zona de acondicionamiento térmico y homogenización dentro del horno, así como un consumo de energía térmica considerable para la vaporización de agua utilizada en el acondicionamiento de las materias primas. Una vez identificadas la fuente de aprovechamiento potencial de calor y el destinatario final de esta energía, se procedió a realizar una caracterización detallada de las fuentes de aprovechamiento y las necesidades requeridas por el proceso de vaporización, de tal manera que se tuviera toda la información para el correcto diseño del sistema de recuperación. El diseño detallado del sistema de recuperación fue una de las etapas, más importantes y desafiantes del proyecto debido a que en este se desarrollaron todos los cálculos estructurales, de materiales y de proceso que garantizarían un correcto funcionamiento y solución a los requerimientos de la oportunidad de mejora planteada. |
Abstract: | For developing the present grade project, was necessary to have knowledge and develop a detailed analysis of Vidrio Andino S.A. company necessities focused on the improvements opportunities for heating recovery. The project initiated with the resource stage and process analysis on which was found heating losses in the thermal conditioning inside the furnace potentially usable, as well as a thermal energy consumption highlighted used for the vaporization of water used on the conditioning of batch raw materials. Once the potential heating recovery was found and the final receipt of this energy, it has been proceed to make a detailed characterization of the sources and required parameters needed by the process in order to have all the complete information to make a properly designed of the heating recovery system. The detailed design of the heating recovery system was one of the important and challenging stages due that in this stage were developed all the estructural, materials, and process calculations that will guarantee an properly working and solving of the required necessities. |
URI: | http://hdl.handle.net/20.500.11839/7324 |
Citation: | APA 6th - Moreno Beltrán, J. D. (2019) Diseño de sistema de recuperación de calor de aire caliente de desecho para calentamiento y vaporización de agua en la compañía Vidrio Andino S.A. (Trabajo de grado). Fundación Universidad de América. Retrieved from http://hdl.handle.net/20.500.11839/7324 |
Appears in Collections: | Planos - Ingeniería Mecánica Trabajos de grado - Ingeniería Mecánica |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
4111350-2019-1-IM.pdf | Diseño de sistema de recuperación de calor de aire caliente... | 24.27 MB | Adobe PDF | View/Open |
4111350-2019-1-IM-Plano1.pdf | Plano-Vista y localización general sistema | 588.45 kB | Adobe PDF | View/Open |
4111350-2019-1-IM-Plano2.pdf | Plano-Ensamble y dimensionamiento general sistema | 1.3 MB | Adobe PDF | View/Open |
4111350-2019-1-IM-Plano3.pdf | Plano-Dimensionamiento sistema extracción aire | 550.57 kB | Adobe PDF | View/Open |
4111350-2019-1-IM-Plano4.pdf | Plano-Componentes sistema extracción aire | 651.73 kB | Adobe PDF | View/Open |
4111350-2019-1-IM-Plano5.pdf | Plano-Dimensionamiento acople tuberta-Damper | 229.49 kB | Adobe PDF | View/Open |
4111350-2019-1-IM-Plano6.pdf | Plano-Dimensionamiento Estructura Soporte Damper | 286 kB | Adobe PDF | View/Open |
4111350-2019-1-IM-Plano7.pdf | Plano-Dimensionamiento platina regulación flujo Damper | 195.74 kB | Adobe PDF | View/Open |
4111350-2019-1-IM-Plano8.pdf | Plano-Dimensionamiento tapa acceso y montaje Damper | 207.41 kB | Adobe PDF | View/Open |
4111350-2019-1-IM-Plano9.pdf | Plano-Sistema accionamiento Damper | 250.63 kB | Adobe PDF | View/Open |
4111350-2019-1-IM-Plano10.pdf | Plano-Componentes sistema transporte aire | 553.37 kB | Adobe PDF | View/Open |
4111350-2019-1-IM-Plano11.pdf | Plano-Dimensionamiento sistema estructural | 533.47 kB | Adobe PDF | View/Open |
4111350-2019-1-IM-Plano12.pdf | Plano-Ensamble & juntas sistema estructural | 624.65 kB | Adobe PDF | View/Open |