Arquitectura
Economía
Ciencias y humanidades
Ingenierías

Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.11839/9056
Título: Diseño conceptual de la planta de tratamiento de aguas residuales del casco urbano del municipio de Pesca, Boyacá
Otros títulos: Conceptual design of the wastewater treatment plant in the urban center of the municipality of Pesca, Boyacá
Autor(es): Cáceres Espinosa, Juan Felipe
Martínez Duarte, Adriana Victoria
Director de tesis: Cuesta Parra, Diana Marceña
Tipo de licencia: Atribución – No comercial
Palabras clave: Agua residual;Bacterias aerobias;Lodos activados;Residual water;Aerobic bacteria;Muds activated;Tesis y disertaciones académicas
Fecha de publicación: 17-ago-2022
Editorial: Fundación Universidad de América
Resumen: En el presente trabajo, se expuso la propuesta de diseño conceptual de una planta de tratamiento de aguas residuales (PTAR) para el municipio de Pesca Boyacá, inicialmente fue necesario realizar un diagnóstico fisicoquímico del agua residual por medio de una muestra compuesta, donde se realizaron pruebas para la determinación de parámetros como DBO,DQO, solidos totales y dureza donde se encontró que los valores de DBO y DQO fueron de 165 mgO2/L y 339 mgO2/L respectivamente, posteriormente fue realizado una comparación de los valores obtenidos previamente con los encontrados en la Resolución 631 del 2015, Resolución 3560 del 2015 y estudios previos presentados por la alcaldía del municipio, donde se evidencia que cada uno de los parámetros obtenidos en el reporte no cumplen con la normatividad, a excepción del pH que está dentro del rango permisible con un valor de 7,2.
Abstract: In the present work, the conceptual design proposal of a wastewater treatment plant (WWTP) for the municipality of Pesca Boyacá was presented, initially it was necessary to carry out a physicochemical diagnosis of the wastewater by means of a composite sample, where tests for the determination of parameters such as BOD, COD, total solids and hardness where it was found that the values ​​of BOD and COD were 165 mgO2/L and 339 mgO2/L respectively, later a comparison of the values ​​obtained previously with the found in Resolution 631 of 2015, Resolution 3560 of 2015 and previous studies presented by the mayor of the municipality, where it is evident that each of the parameters obtained in the report do not comply with the regulations, except for the pH that is within the range allowable with a value of 7.2.
URI: https://hdl.handle.net/20.500.11839/9056
Citación: APA 7th - Cáceres Espinosa, J. F. y Martínez Duarte, A. V. (2022) Diseño conceptual de la planta de tratamiento de aguas residuales del casco urbano del municipio de Pesca, Boyacá. [Trabajo de grado, Fundación Universidad de América] Repositorio Institucional Lumieres. https://hdl.handle.net/20.500.11839/9056
línea de énfasis: Tratamiento de aguas residuales
Aparece en las colecciones:Trabajos de grado - Ingeniería Química

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
6171249-2022-2-IQ.pdf2.25 MBAdobe PDFVisualizar/Abrir
CARTA DE CESIÓN DE DERECHOS Y AUTORIZACIÓN PARA PUBLICACIÓN.pdf
Accesso Restringido
604.84 kBAdobe PDFVisualizar/Abrir    Request a copy


Este ítem está sujeto a una licencia Creative Commons Creative Commons