Título: Diseño de un banco de pruebas para la verificación de la presión de ajuste y el diferencial de cierre de válvulas de alivio con accionamiento por resorte directo y pilotada de 3” de servicio en líquidos.
Otros títulos: Design of a test bench for the verification of the set pressure and the closing differential of relief valves with operation by direct spring and pilot operated 3” service in liquids.
Autor(es): Cortés Rodríguez, Ángel Ernesto
Velandia Álvarez, Juan Sebastián
Director de tesis: Rodríguez Avendaño, Diego Fernando
Tipo de licencia: Atribución – No comercial
Palabras clave: Presión de ajuste;Válvulas de alivio;Verificación;Set pressure;Relief valves;Verification;Tesis y disertaciones académicas
Fecha de publicación: 2-feb-2022
Editorial: Fundación Universidad de América
Resumen: El presente proyecto tiene como finalidad el diseño de un banco de pruebas el cual facilite el proceso de verificación de la presión de ajuste y diferencial de cierre para válvulas de alivio de presión de una medida de 3”, además de seguir con los lineamientos mencionados en la normativa aplicable y de realizar una correcta verificación. Con esto se busca ofrecer una herramienta adecuada que contribuya a reducir posibles errores y accidentes que se producen a la hora de realizar el proceso de verificación de estos dispositivos y con esto reducir accidentes en las empresas por la falta de verificación de las válvulas de seguridad. Se realizo primero una contextualización acerca de los dispositivos de alivio de presión y su funcionamiento, además de una recopilación de las normas aplicables al diseño. Con esto se realizo una interpretación de los datos encontrados y se determinaron los parámetros de diseño para el proyecto; con esto se plantearon 3 alternativas de posible solución y una evaluación de las mismas por medio de una matriz de priorización. Seguido de esto se prosiguió con el diseño detallado de los componentes que conforman la máquina. Final mente se realizaron los manuales de: instalación, operación y mantenimiento, junto con un análisis financiero.
Abstract: The purpose of this project is to design a test bench which facilitates the verification process of the adjustment pressure and closing differential for pressure relief valves of a 3" size, in addition to following the guidelines mentioned in the applicable regulations and to carry out a correct verification. This seeks to offer an adequate tool that contributes to reducing possible errors and accidents that occur when carrying out the verification process of these devices and thereby reduce accidents in companies due to the lack of verification of safety valves. First, a contextualization about the pressure relief devices and their operation was carried out, as well as a compilation of the standards applicable to the design. With this, an interpretation of the data found was made and the design parameters for the project were determined; With this, 3 possible solution alternatives were proposed and an evaluation of them through a prioritization matrix. Following this, the detailed design of the components that make up the machine continued. Finally, the installation, operation and maintenance manuals were made, along with a financial analysis.
URI: https://hdl.handle.net/20.500.11839/8851
Citación: APA 7th - Cortés Rodríguez, Á. E. y Velandia Álvarez, J. S. (2022) Diseño de un banco de pruebas para la verificación de la presión de ajuste y el diferencial de cierre de válvulas de alivio con accionamiento por resorte directo y pilotada de 3” de servicio en líquidos. [Trabajo de grado, Fundación Universidad de América] Repositorio Institucional Lumieres. https://hdl.handle.net/20.500.11839/8851
Aparece en las colecciones:Trabajos de grado - Ingeniería Mecánica