Architecture
Economic and administrative sciences
Sciences and Humanities
Engineering

Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11839/7776
Title: Propuesta de mejora del sistema de tratamiento de agua residual del proceso de clorinación para su reutilización en la empresa Enterna S.A.
Other Titles: Improvement proposal of the waste water system of the chlorination process to reuse in Enterna S.A.
Authors: Diaz Ballesteros, Ashly Veronica
Jimenez Ciro, Vivian Alejandra
License type: Atribución – No comercial – Sin Derivar
Keywords: Agua residual industrial;Industria latex;Industrial wastewater;Rubber industry;Tesis y disertaciones académicas
Issue Date: 18-Feb-2020
Publisher: Fundación Universidad de América
Resumen: La empresa Eterna S.A consume actualmente una amplia cantidad de agua para los diferentes procesos productivos entre ellos se encuentra la producción de guantes de látex, en donde se genera gran parte de efluente específicamente en la fase de clorinado, actualmente cuenta con una planta PTAR en donde se reúnen todos los tipos de efluentes líquidos y se le hace el debido proceso para poder cumplir con los rangos permisibles de vertimientos industriales especificados en la Resolución 0631 de 2015; sin embargo lo que se busca es disminuir en gran parte el consumo extensivo de agua potable en la empresa, es por esto que se busca una alternativa para la posible reutilización del efluente generado en la fase de clorinación. Para solucionar esta problemática se hizo una descripción general de la empresa y proceso productivo, posteriormente se evaluó el consumo de agua por medio de un balance hídrico para poder así realizar una caracterización de los diferentes tipos de efluentes a tratar en donde se evaluaron alrededor de siete parámetros, siendo estos DBO5, DQO, SDT, dureza, conductividad, pH, y cloruros, en donde se estudiaron la relevancia de cada uno de estos en el proceso y como afectan en el producto final, de acuerdo con esto se seleccionó la alternativa de tratamiento más adecuada para tratar el cual incluye procesos como neutralización, coagulación y floculación, filtración y ultrafiltración. Posterior al desarrollo experimental de los procesos ya mencionados se obtuvieron resultados favorables respecto a la disminución de parámetros críticos seleccionados en el efluente. Por último, se procedió a realizar el dimensionamiento de los equipos para su posible implementación a escala industrial y así culminar con el cálculo de los costos operativos y de inversión.
Abstract: The company Eterna S.A currently consumes a large amount of water to the different productive processes among them is the production of latex gloves, where much of the effluent is generated specifically in the chlorination phase, currently has a WTS plant where they meet all types of liquid effluents and due process is done to be able to comply with the permissible ranges of industrial dumping specified in the Resolution 0631 of 2015; however, what is sought is to decrease to a large extent the extensive consumption of drinking water in the company, that is why we are looking for a alternative for the possible reuse of the effluent generated in the phase of chlorination To solve this problem, a general description of the company was made and productive process, subsequently the water consumption was evaluated by means of a water balance to be able to perform a characterization of the different types of effluents to be treated where about seven parameters were evaluated, being these BOD5, COD, SDT, hardness, conductivity, pH, and chlorides, where studied the relevance of each of these in the process and how they affect the final product, according to this the treatment alternative was selected more suitable for treating which includes processes such as neutralization, coagulation and flocculation, filtration and ultrafiltration. After the experimental development of the processes already mentioned favorable results were obtained regarding the decrease of critical parameters selected in the effluent. Finally, we proceeded to perform the sizing of the equipment for possible implementation on an industrial scale and thus culminate with the calculation of operational and investment costs.
URI: http://hdl.handle.net/20.500.11839/7776
Citation: APA 6th - Diaz Ballesteros, A. V. y Jimenez Ciro, V. A. (2020) Propuesta de mejora del sistema de tratamiento de agua residual del proceso de clorinación para su reutilización en la empresa Enterna S.A. (Trabajo de grado). Fundación Universidad de América. Retrieved from http://hdl.handle.net/20.500.11839/7776
Appears in Collections:Trabajos de grado - Ingeniería Química