Title: Propuesta para la mejora en el sistema de tratamiento de aguas residuales para la empresa Analquim Ltda.
Other Titles: Proposal for the improvement in the wastewater treatment system for the Analquim Ltda company
Authors: Montaño Montaño, Claudia Viviana
License type: Atribución – No comercial – Sin Derivar
Keywords: Aguas residuales;Operaciones unitarias;Filtro de membrana;Wastewater;Unit operations;Membrane filter;Tesis y disertaciones académicas
Issue Date: 17-Feb-2020
Publisher: Fundación Universidad de América
Resumen: Este proyecto se desarrolla inicialmente con el estudio del estado actual del agua y de la planta de tratamiento de aguas, luego se propone alternativa de mejora que consta de tres partes para la problemática que se presenta en este momento en la empresa. En primer lugar se tiene la implementación de una trampa de grasas al inicio del proceso del tratamiento del agua; en segundo lugar se tiene el uso de un nuevo coagulante Cloruro Férrico para el proceso de coagulación y floculación; y por último, el uso de una resina mixta de grado electrolítico para los filtros de membrana ubicados a final de la planta de tratamiento. La selección de mejora con el fin de reducir los contaminantes expuestos en el agua que no cumplen con la resolución 631 de 2015. Se analizó las especificaciones técnicas de las alternativas de mejora seleccionadas y sus costos respectivos.
Abstract: This project is initially developed with the study of the current state of the water and the water treatment plant, then an alternative for improvement is proposed that consists of three parts for the problem that is currently presented in the company. First of all there is the implementation of a grease trap at the beginning of the water treatment process; secondly, there is the use of a new ferric chloride coagulant for the coagulation and flocculation process; and finally, the use of a mixed electrolytic grade resin for membrane filters located at the end of the treatment plant. The selection of improvement in order to reduce the contaminants exposed in the water that do not comply with resolution 631 of 2015. The technical specifications of the selected improvement alternatives and their respective costs were analyzed.
URI: http://hdl.handle.net/20.500.11839/7766
Citation: APA 6th - Montaño Montaño, C. V. (2020) Propuesta para la mejora en el sistema de tratamiento de aguas residuales para la empresa Analquim Ltda. (Trabajo de grado). Fundación Universidad de América. Retrieved from http://hdl.handle.net/20.500.11839/7766
Appears in Collections:Trabajos de grado - Ingeniería Química

Files in This Item:
File Description SizeFormat 
6101392-2020-1-IQ.pdf2.55 MBAdobe PDFView/Open
CARTA DE CESIÓN DE DERECHOS Y AUTORIZACIÓN DE PUBLICACIÓN.pdf
Access Restricted
708.58 kBAdobe PDFView/Open    Request a copy


This item is licensed under a Creative Commons Licence Creative Commons