Architecture
Economic and administrative sciences
Sciences and Humanities
Engineering

Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.11839/8260
Title: Evaluación la implementación de centrífugas de velocidad variable de alta capacidad Cen-Tex 1865 para el control de sólidos en la perforación de un pozo del campo E en la Cuenca Llanos Orientales
Other Titles: Evaluation of the implementation of Cen-Tex 1865 high capacity variable speed centrifuges for solids control in the drilling of a well in the e field in the Llanos Orientales Basin
Authors: Ayala Pinzón, Juan David
Gutiérrez García, Camilo Andrés
Thesis advisor: Tovar, Jorge Andrés
License type: Atribución – No comercial
Keywords: Centrífugas alta capacidad;Control sólidos;Perforación de pozos;High capacity centrifuges;Solid controls;Well drilling;Tesis y disertaciones académicas
Issue Date: 15-Feb-2021
Publisher: Fundación Universidad de América
Resumen: Un deficiente proceso de control de sólidos trae consigo consecuencias que se traducen en un aumento de los costos en la operación de perforación, pues se hace necesaria desde una inversión en tratamiento o formulación de nuevos lodos destinados al proyecto, hasta el mantenimiento de equipos que sufren desgaste; se propone a través del presente proyecto de grado una forma de hacer más eficiente el proceso de control de sólidos a partir de la implementación y posterior evaluación del desempeño de centrifugas de alta capacidad Cen-Tex 1865 en un campo de la cuenca de los Llanos Orientales. La validación del proyecto se llevó a cabo a partir de la comparación entre el rendimiento en la remoción de finos, y el tamaño de partícula resultante de la circulación del lodo de perforación en las citadas unidades centrífugas de alta capacidad, contra centrífugas convencionales de baja capacidad Kubco, para lo cual se realizaron pruebas de laboratorio al lodo de perforación a la descarga de cada centrifuga como la prueba de azul de metileno, con resultado de 22,5 lb/bbl en ambos equipos, la prueba de retorta, que en solidos de baja gravedad especifica arrojo 7,7% para la centrifuga Cen-Tex 1865 y 8% para la Kubco, y por último la prueba de Cilas, cuyo resultado para el tamaño de partícula fue de 9,03 micras contra 13,47 micras en cada equipo respectivamente. Finalmente, tras evaluar los indicadores financieros VPN y CAUE se concluyó que la centrifuga Kubco genera menos costos y más ganancias que la centrifuga Cen-Tex 1865, pero a nivel operativo la centrifuga Cen-Tex 1865 permite un ahorro de 539.175.960 COPS diarios en la formulación y disposición final del lodo de perforación, lo que hace de esta, sumado a los resultados de las pruebas de laboratorio la mejor opción en términos de eficiencia operativa.
Abstract: A deficient solids control process brings with it consequences that translate into an increase in costs in the drilling operation, since it is necessary from an investment in treatment or formulation of new mud for the project, to the maintenance of equipment that suffers wear; Through this degree project, a way to make the solids control process more efficient is proposed through the implementation and subsequent performance evaluation of Cen-Tex 1865 high capacity centrifuges in a field in the Llanos Orientales basin. The validation of the project was carried out from the comparison between the performance in the removal of fines, and the particle size resulting from the circulation of the drilling mud in the aforementioned high-capacity centrifugal units, versus conventional low-capacity centrifuges Kubco, for which laboratory tests were carried out on the drilling mud at the discharge of each centrifuge such as the methylene blue test, with a result of 22.5 lb / bbl in both equipment, the retort test, which in solids of Low specific gravity yielded 7.7% for the Cen-Tex 1865 centrifuge and 8% for the Kubco, and finally the Cilas test, whose result for the particle size was 9.03 microns against 13.47 microns in each team respectively. Finally, after evaluating the NPV and EUAC financial indicators, it was concluded that the Kubco centrifuge generates less costs and more profits than the Cen-Tex 1865 centrifuge, but at an operational level the Cen-Tex 1865 centrifuge allows a saving of 539,175,960 COPS per day in the formulation and final disposal of the drilling mud, which makes this, added to the results of the laboratory tests, the best option in terms of operational efficiency.
URI: https://hdl.handle.net/20.500.11839/8260
Citation: APA 7th - Ayala Pinzón, J. D. y Gutiérrez García, C. A. (2021) Evaluación la implementación de centrífugas de velocidad variable de alta capacidad Cen-Tex 1865 para el control de sólidos en la perforación de un pozo del campo E en la Cuenca Llanos Orientales. [Trabajo de grado, Fundación Universidad de América] Repositorio Institucional Lumieres. https://hdl.handle.net/20.500.11839/8260
Appears in Collections:Trabajos de grado - Ingeniería de Petróleos

Files in This Item:
File Description SizeFormat 
5151170-2021-1-IP.pdf2.53 MBAdobe PDFView/Open
CARTA DE CESIÓN DE DERECHOS Y AUTORIZACIÓN PARA PUBLICACIÓN.pdf
Access Restricted
709.56 kBAdobe PDFView/Open    Request a copy


This item is licensed under a Creative Commons Licence Creative Commons