Title: Evaluación del sistema de electrocoagulación para disminuir la carga contaminante a escala de laboratorio
Other Titles: Evaluation of the electrocoagulation system to reduce the pollutant load at laboratory scale
Authors: Hernández Flórez, Johan Sebastian
Mejia Roa, Stephany
Thesis advisor: Gutiérrez Ruíz, Myriam
License type: Atribución – No comercial
Keywords: Electrocoagulación;Tratamiento de aguas;Carga orgánica;Procesos de oxidación avanzada;Electrocoagulation;Water treatment;Organic load;Advanced oxidation processes;Tesis y disertaciones académicas
Issue Date: 14-Feb-2019
Publisher: Fundación Universidad de América
Resumen: Este trabajo de grado se realizó para evaluar el método de electrocoagulación para el tratamiento de aguas de la empresa PMP cuyos vertimientos se caracterizan por el contenido de carga orgánica, se encontró que estos vertimientos tenían un valor de grasas y aceites de 1264 mg/L , sólidos suspendidos de 17814 mg/L, sólidos sedimentables de 24007 mg/L, DQO DE 85229 mg/L O2 y DBO de 12308 mg/ L O2. Posterior al diagnóstico se definieron las variables del método de electrocoagulación como lo son pH, densidad de corriente, temperatura, material del electrodo y tiempo de reacción. Se realizó dos experimentaciones, para la primera experimentación fue necesario hacer una prueba preliminar donde se evaluó el método de electrocoagulación en un tiempo de 15 y 60 minutos con un voltaje de 2V, esto con el fin de identificar si para remover la carga contaminante de los vertimientos de PMP es suficiente este tiempo, el resultado de esta prueba preliminar no fue el esperado por esta razón se decide realizar la primera experimentación en un tiempo de 1, 2, 3, 4, 5 y 6 horas, con un voltaje de 2V y electrodos de hierro y aluminio, como resultado se obtuvo que el tiempo adecuado para la remoción de contaminar de la empresa es 4 horas obteniendo una remoción mayor al 80% . Al comprar este resultado con los resultados encontrados en la bibliografía se identifica que el tiempo es demasiado alto para el método de electrocoagulación, por esta razón se realizó una segunda experimentación donde se evaluó el método utilizando electrodos de hierro, un voltaje de 2,7V, 7,7V y 12,6V y un tiempo de 5, 15 y 30 minutos, se obtuvo como resultado que para un voltaje de 12,6 V y un tiempo de 30 min se removió más del 90% para los parámetros DQO, sólidos suspendidos, sólidos sedimentables y grasas y aceites.
Abstract: This work of degree was carried out to evaluate the method of electrocoagulation for the water treatment of the company PMP whose discharges are characterized by the content of organic load, it was found that these discharges had a value of fats and oils of 1264 mg / L, suspended solids of 17814 mg / L, sedimentable solids of 24007 mg / L, COD DE 85229 mg / L O2 and BOD of 12308 mg / L O2. After the diagnosis, the variables of the electrocoagulation method were defined, such as pH, current density, temperature, electrode material and reaction time. Two experiments were carried out, for the first experimentation it was necessary to do a preliminary test where the electrocoagulation method was evaluated in a time of 15 and 60 minutes with a voltage of 2V, this in order to identify if to remove the pollutant load of the PMP discharges is sufficient this time, the result of this preliminary test was not the expected for this reason it is decided to perform the first experimentation in a time of 1, 2, 3, 4, 5 and 6 hours, with a voltage of 2V and iron and aluminum electrodes, as a result it was obtained that the appropriate time for the removal of contaminants from the company is 4 hours obtaining a removal greater than 80%. When buying this result with the results found in the bibliography it is identified that the time is too high for the electrocoagulation method, for this reason a second experimentation was carried out where the method was evaluated using iron electrodes, a voltage of 2.7V, 7.7V and 12.6V and a time of 5, 15 and 30 minutes, was obtained as a result that for a voltage of 12.6 V and a time of 30 min was removed more than 90% for the parameters COD, suspended solids , sedimentables solids and fats and oils.
URI: http://hdl.handle.net/20.500.11839/7384
Citation: APA 6th - Hernández Flórez, J. S. y Mejia Roa, S. (2019) Evaluación del sistema de electrocoagulación para disminuir la carga contaminante a escala de laboratorio (Trabajo de grado). Fundación Universidad de América. Retrieved from http://hdl.handle.net/20.500.11839/7384
Appears in Collections:Trabajos de grado - Ingeniería Química