Título: Evaluación del efecto de diferentes morteros sobre las propiedades de pisos autonivelantes a escala laboratorio
Otros títulos: Evaluation of the effect of different mortars on the properties of self-leveling floors at laboratory scale
Autor(es): Paredes Gutiérrez, Sergio Felipe
Tipo de licencia: Atribución – No comercial
Palabras clave: Autonivelante;Compresión;Mortero;Self-leveling;Compression;Mortar;Tesis y disertaciones académicas
Fecha de publicación: 15-ago-2018
Editorial: Fundación Universidad de América
Resumen: El presente proyecto se desarrolló en una empresa, el cual tiene como finalidad evaluar los diferentes morteros sobre las propiedades de pisos autonivelantes comparando los pisos comerciales Piso comercial N° 1 y Piso comercial N° 2 que actualmente se encuentran en el portafolio de CI. Teniendo en cuenta la revisión de literatura realizada y los ensayos llevados a cabo siguiendo las normas ASTM y NTC, se conocerá cuál de estos 8 pisos tienen el mejor rendimiento estudiando no solo las variaciones químicas sino también todos los factores que pueden afectar el desempeño y aplicabilidad, siendo estos los pisos autonivelantes, a los que se desea mejorar sus propiedades mecánicas como la contracción, resistencia a la abrasión (prueba taber test y chorro de corindón), flujo libre, contenido de aire, resistencia a la compresión y adherencia. Donde se variarán los tipos de arenas (30/100 - 16/50) y binder (B1, B2, B3 y B4) comparando así los resultados con los dos pisos comerciales existentes (Piso comercial N° 1 y Piso comercial N° 2).
Abstract: The present project was developed in a company, which aims to evaluate the different mortars on the properties of self-leveling floors comparing the commercial floors Commercial Floor No. 1 and Commercial Floor No. 2 that are currently in the CI portfolio. Taking into account the review of the literature and the tests carried out following the ASTM and NTC standards, it will be known which of these 8 floors have the best performance by studying not only the chemical variations but also all the factors that may affect the performance and applicability , these being the self-leveling floors, to which it is desired to improve their mechanical properties such as shrinkage, resistance to abrasion (taber test and corundum jet), free flow, air content, resistance to compression and adhesion. Where sand types will be varied (30/100 - 16/50) and binder (B1, B2, B3 and B4) comparing the results with the two existing commercial floors (Commercial floor N ° 1 and Commercial floor N ° 2) .
URI: http://hdl.handle.net/20.500.11839/6960
Citación: APA 6th - Paredes Gutiérrez, S. F. (2018) Evaluación del efecto de diferentes morteros sobre las propiedades de pisos autonivelantes a escala laboratorio (Monografía). Fundación Universidad de América. Retrieved from http://hdl.handle.net/20.500.11839/6960
Aparece en las colecciones:Trabajos de grado - Ingeniería Química

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
6082056-2018-2-IQ.pdf7.27 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Creative Commons